Client: London Borough of Hillingdon
Problem
The balcony and two flights of stairs were in a state of deterioration and as a result had lost its ability to prevent water ingress and also was considered a danger due to its slippery surface.
Solution
Spray apply SuperDeck Cold Applied Membrane to an average thickness of 1.5mm incorporating a fine black quartz aggregate to promote slip resistance and maintain a aesthetically pleasing finish.
Result
An instant hard wearing, waterproof, easily cleaned, slip resistant membrane that was returned back to service within 1 hour of application.
Client: Abingdon Borough Council
Problem
The surface to the Balcony was suffering severe problems and heavily leaking water through
Solution
Remove all unsound coatings by scabbling. Squeegee apply SuperDeck to form a waterproof skid resistant & highly attractive finis.
Client: Middlesbrough Borough Council
Problem
The GRC Promenade Tiles had become slippery with age and the asphalt
waterproofing under had become porous and was leaking
Solution
The Promenade tiles were cleaned & prepared and any loose ones
were repaired. SuperDeck was spray and squeegee applied to level surface
up and produce a waterproof slip resistant surface in different colours
to different areas.
|